Test Results |
TEST METHOD | DESCRIPTION | REMARKS/RESULTS | TESTED BY |
ASTM B-117 |
Corrosion resistance test. The test was performed on a bright red panel. This test provides a controlled corrosive environment which produces relative corrosion resistance information. The salt spray (fog) duration was 1000 hours. | Light blistering, no peeling. | Bodycote Technitrol Inc. |
ASTM D-3359 |
|
Result: Rating of 5. This is the best rating that can be obtained using this method. | Bodycote Technitrol Inc. |
ASTM D-2246 |
|
No cracking. No blistering. Very good gloss retention. |
Bodycote Technitrol Inc. |
|
|
No blistering. No peeling. Very good gloss retention. |
Peter J. Rice Associates & Bodycote |
ASTM D-4060 |
|
Average loss 0.017g. at 100 cycles. | Bodycote Technitrol Inc. |
ASTM D-522 |
|
No cracks @ 135°. No peeling @ 135°. |
Bodycote Technitrol Inc. |
ASTM D-96 |
|
9.4 perm (inch-pound) or 5.37 x 10-7 g/pa*s*m2 considered a good value for a breathable coating. | Bodycote Technitrol Inc. |
|
|
237g/liter VOC. |
|
ASTM D1308 |
|
No noticeable effect. |
Bodycote Technitrol Inc. |
Gardner Impact Test |
|
No cracks. No peeling. |
Bodycote Technitrol Inc. |
ASTM D4541 Tensile ( pull off ) Adhesion |
Using Pneumatic Adhesion Tensile Testing Instrument (PATTI) on a substrate of gel coat fiberglass reinforced plastic (FRP).
|
The adhesion of the AST D45 exceeded the cohesion strength of the FRP laminate.( avg. PSI 597.7; range 529.6 – 713.3 ) | KTA-TATOR Inc. |
ASTM D3363 Pencil Hardness |
The pencil
hardness of the AST D45 on Fibreglass Reinforced Plastic (FRP) laminate
and gel coat was evaluated.
|
Pencil Hardness at 2 H. | KTA-TATOR Inc. |